Safety Light Curtains |
Omron's Wide Selection of Safety Light Curtains Guarantees You'll Get Exactly What you Need |
Powerful Solutions for Today's Tough Automation Guarding Problems |
| |
Omron Scientific Technologies, Inc. provides seven safety light curtain families to solve your optical guarding needs. From compact models designed for machine locations where space is tight, to larger, robust light curtains powerful enough to guard large perimeters. Omron STI offers you a choice, because when it comes to automation safeguarding, one size does not fit all. |
Optimized Performance |
| |
Omron STI safety light curtains are fit for use - meaning, you can select a safety light curtain in the size and with the specifications you need to optimize performance. Our safety light curtain designs allow you to tailor a system for the lowest possible system cost, so you're only paying for what you need. |
Unbiased Recommendation |
| |
Supplying such an extensive array of safety light curtains and controls guarantees that Omron STI will give you an unbiased recommendation for what will work best in your particular situation. Our wide product line means you don't have to struggle to "make one fit." We don't have to force your application to fit our safety light curtain. From tight spaces to perimeter guarding, we provide the correct product for the job. |
Ultimate Flexibility Allows for Lower Cost Solutions |
| |
The MC4700 safety light curtain family offers the greatest number of possible configurations, more than any other safety light curtain in the world. The MC4700 safety light curtain combines fast response time with either 12, 14, 20, or 30 mm object resolutions. The protected height range and coverage of the MC4700 family is impressive. And now with the introduction of the "Jointed" MCJ4700, the first safety light curtain with an elector-mechanical joint, Omron STI's 4700 series is revolutionary. Omron STI allows you to buy just what you need to buy. The MC4700, MCF4700, and MCJ4700 can be ordered with different object resolutions within a system. The various object resolutions within a and multi-segmented systems allow you to best fit the guarding to your application, and therefore you only pay for what you need. |
|


|
Laser Light Safety Scanner: OptoShield OS3101 |
- Safety range of 4 m
- Configured via easy-to-use software
- Intrusion indicators immediately identify where the safety zone is encroached
- Two-digit numeric display for diagnostic codes
- LED indicators for status and diagnostics
- Two separate detection sets (each with one safety zone and one warning zone) can be externally selected
- Choice of two scanning configuration modes: graphic coordinate or sculpting
- Two PNP safety outputs designed to directly switch machine primary control elements (MPCE) at 625 mA, 24 VDC
Auxiliary output for Warning Zone
- Operating Modes: Automatic Start, Start Interlock and Start/Restart Interlock
- EDM/MPCE monitoring
- No separate control box required
- Response time as fast as 80 ms
- Compact size – 155 x 182 x 156 mm (6.1 x 7.2 x 6.1 in.)
|
|
Device Net Safety System |
Introducing a Safety Network System that dramatically alters previous safety design. Programmable safety circuits are incorporated to facilitate efficient designing and for distributed allocation through the network. DeviceNet wiring on the existing network can be used as is, facilitating efficient design by expanding on the existing system. The programmability of safety circuits, expandability of I/O using the network, and compatibility with the DeviceNet open network effects major changes to the framework of previous safety design systems.
Safety DeviceNet Network Controller - NE1A
Omron's new NE1A Safety DeviceNet Controller revolutionizes safety systems the way PLCs changed industrial automation from relay panels to flexible operation. Communicate safety system status via DeviceNet to your plant floor production control system using Omron's easy-to-use Safety DeviceNet Configurator software. Achieve significant wiring and testing savings by using one DeviceNet network to communicate both safety and production information. Easily change or upgrade the safety system with program changes instead of wiring changes.
- Integrate complex safety schemes with easy-to-use drag-and-drop programming
- Communicates both safety system and machine control status information over a single DeviceNet network, reducing wiring costs.
- DeviceNet Safety--a proven, open platform certified for safety applications.
|


|
Light Curtains |
F3SJ-A Economical Safety Light Curtains with No Dead Zone
|
|

|
|
F3S-A Safety Light
Curtain |
|
Meets OSHA, Canadian, and worldwide standards
for
safeguarding personnel from moving
machinery.
Self-contained design with no control
box.
UL and CSA Listed.
Beam spacing of 10 or 20 mm.
Protective height ranges from 140 to 940
mm.
Connect multiple units for a larger
zone.
M12 connectors. |
|
F3S-B Safety
Light Curtain |
|
Type 2 safety light curtain operates
independently or as part of safety systems.
Meets category 2, 1 or B.
Official certification as Type 2
Electro--Sensitive Protective Equipment (ESPE).
Units available with an axis pitch of 25 mm
(hand protection)
in protective heights from 300 mm to
1650 mm.
M12 connectors. |
|
F3SN-A Safety
Light Curtain |
|
Programmable, Type 4 safety light
curtain.
Self-contained, no control box needed.
Serial connectable.
Small, space-saving profile.
Indicator LEDs located directly on the emitter
and receiver.
Available in single beam increments.
Meets ANSI / RIA, OSHA, IEC, EN standards. |
|
F3G-C Laser Safety Area
Scanner |
 |
Increases safety by detecting workers to warn of
proximity to dangerous area.
Protects 300° area.
Long-range sensing is provided up to a 6-m
radius for
the Protective Field and a 7.5-m radius for
the Warning
Field.
|
|
Safety Relay |
Control reliability is mandated in U.S. and European standards for safety implemented circuits. These criteria can be met by using redundant safety-rated device outputs in conjunction with a safety relay.
Safety relays range in function from stop motion detection to 2 -hand palm button control, to dual channel input units with time-delayed outputs that provide conformity to ANSI B11.19, Section 5.1.
All safety relays carry the CE mark and are UL and C-UL listed.
 |
 |
|
Safety Switches |
Omron Scientific Technologies, Inc. safety switches are designed to work together with hinged, sliding, or lift-off guards and barriers. When the guard is opened, the power supply to the machine is disconnected

|
 |
|
|
|
|
|